80
CONTROL I/O INPUT FUNCTIONS
INF-01: Capability of Input Terminal A1
INF-02 : Capability of Input Terminal A2
INF-03: Capability of Input Terminal A3
INF-04: Capability of Input Terminal A4
INF-05: Capability of Input Terminal A5
INF-06: Capability of Input Terminal A6
Setting
Default
Parameter Description
0 No capability
1 Zero
2 Tare
3 Batch start
4 Emergency stop
5 Discharge start
6 Key enable
7 Automatic free fall command
8 Disable thumbwheel switch read
9 Clear tare
10 Accumulation command
11 Cancel previous accumulation
12 Clear accumulation
13 Hold
1 2 3 4 5 6
14 Print command for manual print
User’s settings
CONTROL I/O OUTPUT FUNCTIONS
OUTF-01: Capability of Output Terminal B1
OUTF-02: Capability of Output Terminal B2
OUTF-03: Capability of Output Terminal B3
OUTF-04: Capability of Output Terminal B4
OUTF-05: Capability of Output Terminal B5
OUTF-06: Capability of Output Terminal B6
OUTF-07: Capability of Output Terminal B7
OUTF-08: Capability of Output Terminal B8
Setting
Default
Parameter Description
0 No capability
1 Zero range
2 Underlimit/ Hi-Hi
3 Overlimit/Hi
4 Full flow/ Full/ Go
5 Medium flow/ Lo
6 Dribble flow/ Lo-Lo
7 Discharge
8 Batch Finish
9 Stability
10 Online
11 Weighing sequence running
12 Weighing sequence error
13 Input acknowledge
14 Zero range error
15 Weighing capacity overflow
1 2 3 4 5 6 7 8
16 Low battery
User’s settings