79
Setting
SQF- Name User’s Default
Parameter Description
12
Dribble-flow
comparator
inhibitor timer
0.0 N/A
13
Judgment wait
timer
0.1
0:Until next Batch
Start
14
Batch Finish
output width
0.0
0.0 to 25.5
(In step of 0.1
second)
Non-0: Set time
0: Unused
15
Batch
monitoring
timer
0
0.0 to 25.5
(In step of 1
second)
Non-0: Set time
16
Supplementary
Flow open timer
0.10
0.0 to 25.5
(In step of 0.01
second)
17
Supplementary
Flow close
timer
0.1
Only effective in
Built-In-Automatic Program
mode.
18
Discharging
start wait timer
0.0
19
Discharging
valve close wait
timer
0.1
0.0 to 25.5
(In step of 0.1
second)
Intentionally blank
0: Unused
20
Discharging
time monitor
timer
0
0.0 to 25.5
(In step of 1
second)
Non-0: Set time
Only normal batching (built-in
automatic program mode) is
effective
0 Does not add the final
21
Add the final to
zero band
setting
0
1 Adds the final
0 Does not add the final
22
Add the final to
full setting
0
1 Adds the final
Only loss-in-weight is
effective