9-4 OP-05 SETPOINT UNIT
The OP-05 setpoint unit is a thumbwheel switch unit designed for setting the setpoints exclusive for Batch weighing and
Loss-in-weighting use. By connecting this option to the AD-4401, each setpoint can be set with the thumbwheel switch on
the panel or the BCD input. Since up to 10 of these optional units can be connected in series, the setpoints can be easily
switched through an external unit.
Note
• When the minimum division is set to 10 or more, ten times the value set on the OP-05 will be used.
• When using this option, set the setpoint read mode SPF-01 to “2.”
Setting
SPF- Name Default
Parameter Description
0 Thumbwheel switch Unrequired mode
1 5-digit mode
01
Setpoint
value read
mode
0
2 16-digit mode
GENERAL SPECIFICATION
General Specification
Power supply 11.5 to 25 V DC (Unrequired when external setting input or serial connection is not used)
Power consumption 3.5 W at maximum
Working temperature
-5 °C to 40 °C
Weight Approx. 1 kg
Outer dimensions 192(W) x 118.6(D) x 57(H) mm (See the appearance drawing)
Setpoint parameter
Final (5 digits) / Free fall (3 digits) / Preliminary ( 4 digits)/ Overlimit (2 digits)/ Underlimit (2 digits)
INT/EXT, switching by the slide switch on the front panel
Setpoint Values Which Can
Be Set Externally
Final (5 digits. No input of 8 x 104) / Free fall (3 digits) / Preliminary (4 digits)