17
SETTING WITH THE 16-DIGIT THUMBWHEEL SWITCH (SPF - 01 = 2)
This method assigns an exclusive thumbwheel switch to each setpoint. Some setpoints are set with the front panel keys
without using the thumbwheel switch.
Assignment of the thumbwheel switch and the front panel keys differs depending on the weighing mode (CALF-14)
Since the setpoint assigned to the thumbwheel switch is read in real time, it can be referred to by key operation, but it
cannot be altered. The following shows assignment of the setpoints.
Normal Batching (Customer Programmed Control Mode) (CALF-14=1)
Normal Batching (built-in Automatic Program Mode) (CALF-14=3)
For the thumbwheel switches Final (5 digits), Free Fall (3 digits), Preliminary (4 digits) Over Limit (2 digits),
Under Limit (2 digits)
For the key switches Option Prelim, Zero Band
Loss-in-weight (Customer Programmed Control Mode) (CALF-14=2)
Loss-in-weight (built-in Automatic Program Mode) (CALF-14=4)
For the thumbwheel switches Final (5 digits), Free Fall (3 digits), Preliminary (4 digits)
Over Limit (2 digits), Under Limit (2 digits)
For the key switches Full, Zero Band
Check Weighing Mode 1 (CALF-14=5)
Check Weighing Mode 2 (CALF-14=6)
For the thumbwheel switches Lo (5 digits), Hi (5 digits)
For the key switches Zero Band, Lo-Lo, Hi-Hi
Check Weighing Mode 3 (CALF-14=7)
For the thumbwheel switches Lo-Lo (4 digits), Lo (4 digits), Hi (4 digits), Hi-Hi (4 digits)
For the key switches Zero Band
Check Weighing Mode 4 (CALF-14=8)
* For setting with the front panel keys, see “Setting with the Key Switches (SPF - 01 = 0).”
* When the minimum graduation setting (CALF-03) is 10 or more, 10 will multiply the value set with the thumbwheel
switch.