A&D OP-05 Spécifications Page 30

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 90
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 29
28
6-2 WEIGHING SEQUENCE RELATED
Setting
SQF- Name Default
Parameter Description
1 Internal count
01
Selection of
comparison
weight
1
2 Display count
See 7-6 for details.
0 No Automatic accumulation
1
Accumulates only acceptable
weight
See 7-8 for details.
02
Automatic
accumulation
0
2 Accumulates all values
0
No automatic free fall
compensation
1
Moving average of last four
times (See 7-9 for details.)
Only effective in Batch
weighing mode
03
Automatic free
fall
compensation
0
2
Fuzzy automatic free fall
compensation (See 7-10 for
details.)
Only effective in
Built-In-Automatic Program
mode.
04
Automatic free
fall effective
width.
0
0 to
99999999
Automatic free fall
compensation is made if a
loaded weight is within the final
+/- automatic free fall effective
width.
Only effective in Batch
weighing mode.
05
Unstable
Dribble Flow
Timer
3.0
0.0 to 25.5
(In step of
0.1 second)
If Dribble Flow-time is shorter
than the setting, the preset
Free Fall is applied to the
weighing instead of the
Auto-Free-Fall compensation.
1 Real-time comparison
06
Overlimit/underl
imit operation
2
2
Synchronized with Batch Finish
Output
0 Not required
07
Stability at
judgment
1
1 Required
0: Unused
08
Maximum
number of
supplementary
flow times
0 0 to 255
Non-0: Set times
Only effective in
Built-In-Automatic Program
mode.
Vue de la page 29
1 2 ... 25 26 27 28 29 30 31 32 33 34 35 ... 89 90

Commentaires sur ces manuels

Pas de commentaire