A&D AD-4408C Manuel d'instructions

Naviguer en ligne ou télécharger Manuel d'instructions pour Mesure, test et contrôle A&D AD-4408C. A&D AD-4408C Instruction manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - AD-4408C

AD-4408C Weighing Indicator INSTRUCTION MANUAL 1WMPD4001849A

Page 2 - WARNING DEFINITIONS

AD-4408C Weighing Indicator Page 8 4. Description of Each Part 4.1. Front Panel Fig.1 Front panel Displays No. Name Description 1

Page 3 - Contents

Page 9 AD-4408C Weighing Indicator Key switches No. Name Description 11 • The key to turn the indicator ON (Weighing mode) and OFF (OFF mode)

Page 4

AD-4408C Weighing Indicator Page 10 4.2. Rear Panel Fig.2 Rear panel No. Name Description 1 Terminal block See the detailed desc

Page 5 - 1. Safety Precautions

Page 11 AD-4408C Weighing Indicator 3 CC-Link status LEDs LED ON OFF Blinking RUN Normal • Resetting • No signal SD Transmitting RD

Page 6 - 2. Introduction

AD-4408C Weighing Indicator Page 12 5. Installation 5.1. Precautions 5.1.1. Environment The operating temperature is -10°C to +40°C. D

Page 7 - 3. Specifications

Page 13 AD-4408C Weighing Indicator 5.1.2. Power source Before connecting the indicator to the power source, read the instruction manual thor

Page 8 - 3.3. General

AD-4408C Weighing Indicator Page 14 5.4. Load Cell Connection Two types of load cell connection are available: 6-wire connection and 4-wire connect

Page 9

Page 15 AD-4408C Weighing Indicator Type Advantages Disadvantages Description 6-wire connection (recommended) The error is small even when the

Page 10 - 4. Description of Each Part

AD-4408C Weighing Indicator Page 16 6. Operation 6.1. General Function 6.1.1. Zero adjustment Zero adjustment is a function to set the gross wei

Page 11 - AD-4408C Weighing Indicator

Page 17 AD-4408C Weighing Indicator 6.1.3. Tare Tare is a function to store the gross weight as the tare value and set the net weight to zero.

Page 12 - 4.2. Rear Panel

WARNING DEFINITIONS The warnings described in this manual have the following meanings: A potentially hazardous situation which, if not avoided, c

Page 13

AD-4408C Weighing Indicator Page 18 6.1.5.  display Assign a function to the  display in the general functions. Functions related to the  disp

Page 14 - Washer Screw

Page 19 AD-4408C Weighing Indicator 6.2. Mode Map The indicator has several modes to perform various operations. Perform mode switching by key

Page 15 - 5.2. Load Cell Cable Type

AD-4408C Weighing Indicator Page 20 7. Calibration 7.1. General Description In the calibration mode, the operation to relate the output voltage f

Page 16 - 5.4. Load Cell Connection

Page 21 AD-4408C Weighing Indicator 7.2. Calibration With an Actual Load (Cal5et) Calibration is performed using a calibration weight Before

Page 17

AD-4408C Weighing Indicator Page 22 Step 8 Press the ESC key. Cal5et is displayed and the calibration data is written into the EEPROM. The curre

Page 18 - 6. Operation

Page 23 AD-4408C Weighing Indicator 7.3. Calibration-Related Functions (Calf) Step 1 Press the ON/OFF key to turn the indicator ON (weighing m

Page 19

AD-4408C Weighing Indicator Page 24 Function No. Parameter or Setting range Function Description Default value Calf01 0 to 3 Unit Unit of the weigh

Page 20 - fncf02

Page 25 AD-4408C Weighing Indicator Function No. Parameter or Setting range Function Description Default value Calf06 0.0 to 5.0 Zero tracking

Page 21 - 6.2. Mode Map

AD-4408C Weighing Indicator Page 26 Function No. Parameter or Setting range Function Description Default value Calf08 0.0 to 9.9 Stability detectio

Page 22 - 7. Calibration

Page 27 AD-4408C Weighing Indicator Function No. Parameter or Setting range Function Description Default value Calf13 1 to 3 Over at negative g

Page 23

Page 1 AD-4408C Weighing Indicator Contents 1. Safety Precautions ...

Page 24

AD-4408C Weighing Indicator Page 28 NOTE: Record the setting values of Calf17, 18 and 19 in the “Setting List” at the end of the

Page 25

Page 29 AD-4408C Weighing Indicator 7.4. Calibration Errors When an error occurs during calibration, the error number is displayed. If calibrat

Page 26

AD-4408C Weighing Indicator Page 30 7.5. Load Cell Output Adjustment Add a resistor as shown below to adjust the load cell output. Use a resistor w

Page 27 - 0.0 to 9.9

Page 31 AD-4408C Weighing Indicator 8. General Functions General functions are divided into groups per function and are indicated by the group

Page 28

AD-4408C Weighing Indicator Page 32 Step 6 Press the ESC key. The function number disappears and the indicator returns to the state of step 2. Pre

Page 29

Page 33 AD-4408C Weighing Indicator 8.2. Basic Functions (fncf) Function No. Parameter or Setting range Function Description Default value Ff

Page 30

AD-4408C Weighing Indicator Page 34 8.3. Standard Serial Output (Cl f) Function No. Parameter or Setting range Function Description Default value

Page 31

Page 35 AD-4408C Weighing Indicator 9. Interface 9.1. Standard Serial Output The standard serial output with 0 to 20 mA can be connected to a

Page 32

AD-4408C Weighing Indicator Page 36 9.1.2. Output data The data format used is A&D standard format. This is a format to be used with an A&D

Page 33 - 8. General Functions

Page 37 AD-4408C Weighing Indicator 9.1.3. Data transfer mode Three data transfer modes are available; stream, auto printing and manual printing

Page 34

AD-4408C Weighing Indicator Page 2 11. Setting List...

Page 35

AD-4408C Weighing Indicator Page 38 Status LEDs LED ON OFF Blinking RUN Normal • Resetting • No signal SD Transmitting RD Receiving

Page 36 - (See the NOTE below)

Page 39 AD-4408C Weighing Indicator 9.2.1. Address map Remote register (Number of occupied stations: 4) Addresses are examples when the station

Page 37 - 9. Interface

AD-4408C Weighing Indicator Page 40 Numeric values of the remote register All the values are hexadecimal. Negative values are expressed by the two’

Page 38

Page 41 AD-4408C Weighing Indicator Remote I/O (Number of occupied stations: 4) Addresses are examples when the station number is set to 1. A

Page 39 - CC f01 to CC f04

AD-4408C Weighing Indicator Page 42 AD-4408C --> Master station Master station --> AD-4408C Station Remote input Buffer memory Name Remote

Page 40

Page 43 AD-4408C Weighing Indicator Remote I/O (Number of occupied stations: 2) Addresses are examples when the station number is set to 1. A

Page 41

AD-4408C Weighing Indicator Page 44 AD-4408C --> Master station Master station --> AD-4408C Station Remote input Buffer memory Name Remote

Page 42

Page 45 AD-4408C Weighing Indicator Remote I/O (Number of occupied stations: 1) Addresses are examples when the station number is set to 1. A

Page 43

AD-4408C Weighing Indicator Page 46 9.2.2. Commands The write command is used to send a command to the AD-4408C from the master station. For details

Page 44

Page 47 AD-4408C Weighing Indicator Resuming from suspended modes When the AD-4408C is in a mode that suspends weighing, such as calibration or

Page 45

Page 3 AD-4408C Weighing Indicator 1. Safety Precautions For safe and correct usage, read the following precautions carefully before using the

Page 46

AD-4408C Weighing Indicator Page 48 Write command Specify the data type to write by the command No. (RWw000E). Place the data to write in the comman

Page 47

Page 49 AD-4408C Weighing Indicator Error status flag When an error occurs to the AD-4408C, the remote READY flag (RX007B) becomes inactive and

Page 48 - Remote READY flag (RX007B)

AD-4408C Weighing Indicator Page 50 10. Maintenance 10.1. Error Messages If an error message is displayed, refer to the chart below to take proper

Page 49

Page 51 AD-4408C Weighing Indicator Display Item to be checked Chckey Key switches Chc Cl Standard serial output Chc CC CC-Link Chc r5 Testing

Page 50

AD-4408C Weighing Indicator Page 52 10.2.4. Checking the CC-Link With Chc CC displayed, press the ENTER key to enter the CC-Link check mode. P

Page 51

Page 53 AD-4408C Weighing Indicator 10.2.8. Checking the program version With Chcpr9 displayed, press the ENTER key to display the version of

Page 52 - 10. Maintenance

AD-4408C Weighing Indicator Page 54 10.3. Initialization Mode The initialization restores the contents of the battery backup RAM and EEPROM to the

Page 53

Page 55 AD-4408C Weighing Indicator 10.3.2. All data initialization Step 1 Remove the cover concealing the CAL key and press the CAL key.

Page 54 - 88. 8888

AD-4408C Weighing Indicator Page 56 10.4. Checking the Load Cell Connection Using the Digital Multimeter Using the digital multimeter, load cell

Page 55

Page 57 AD-4408C Weighing Indicator If the AD-4408C does not function properly, contact the nearest A&D dealer. Use the chart below to write

Page 56 - 10.3. Initialization Mode

AD-4408C Weighing Indicator Page 4 2. Introduction The AD-4408C is a weighing indicator that amplifies signals from a load cell, converts it to

Page 57

AD-4408C Weighing Indicator Page 58 11. Setting List When performing maintenance, use the following list as a memo. In case of inquiry about the pr

Page 58

Page 59 AD-4408C Weighing Indicator 11.2. Standard Serial Output Function No. Parameter or Setting range Description Default value User settin

Page 59

AD-4408C Weighing Indicator Page 60 11.4. Calibration-Related Functions Function No. Parameter or Setting range Description Default value User set

Page 60 - 11. Setting List

Page 61 AD-4408C Weighing Indicator Function No. Parameter or Setting range Description Default value User setting Calf13 1 to 3 Condition to

Page 61

AD-4408C Weighing Indicator Page 62 12. External Dimensions Unit: mm Fig.16 External dimensions

Page 62

Page 63 AD-4408C Weighing Indicator MEMO

Page 63

AD-4408C Weighing Indicator Page 64 MEMO

Page 65

3-23-14 Higashi-Ikebukuro, Toshima-ku, Tokyo 170-0013 JAPAN Telephone: [81] (3) 5391-6132 Fax: [81] (3) 53

Page 66 - Page 64

Page 5 AD-4408C Weighing Indicator 3. Specifications 3.1. Analog Section Input sensitivity 0.15 μV/d or greater Input voltage range -35 mV

Page 67

AD-4408C Weighing Indicator Page 6 3.3. General 3.3.1. Interface Standard serial output Output for communication with A&D peripheral devices (

Page 68

Page 7 AD-4408C Weighing Indicator 3.3.3. Other Data backup • Zero value and tare weight Memory backup by lithium battery. (Approx. 10 years

Commentaires sur ces manuels

Pas de commentaire