Page 54 AD-4406 Weighing Indicator
15. Relay Output & Control Input (OP-05)
Replacing the RS-232C interface with this option, 3-relay outputs and 3-control inputs
can be used with the RS-232C interface of this option.
RS-232C functions and pin connections are the same as the RS-232C interface
described in “13. RS-232C Interface (OP-04, OP-05, OP-08)”.
The control inputs can control the indicator from an external terminal just like the front
panel key operations.
Set the external control functions at F13 - F15 of the F-Functions.
When connecting each function pin to the common pin, the indicator makes the action.
Keep a signal width of more than 100 ms for the On-time and Off-time.
ON (Make)
More than 100 ms More than 100 ms
OFF (Break)
The relays output the result of comparison.
Solid-state-relay
Maximum voltage 50VDC
Maximum current 100 mA DC
Maximum resistance 8 Ω
Pin connections (DIN 8 pin connector)
Function Pin No. Signal name Direction Description
1 HI Output Relay output HI
6 OK Output Relay output OK
4 LO Output Relay output LO
Relay
output
8 COM (out) - Relay common terminal
3 EXT1 Input Control input 1 (F13)
5 EXT2 Input Control input 2 (F14)
7 EXT3 Input Control input 3 (F15)
Control
input
2 COM (in) - Control input common
Adaptable connector JA-TCP0586 (an accessory)
Circuit
HI
OK
LO
COM
out)
i
EXT3
EXT2
EXT1
+7~9V
680Ω
680Ω
680Ω
COM
(in)
DIN connector
of OP-05
Control input Relay output
15. Relay Output & Control Input (OP-05)