Page 70 AD-4402
7.5.8.
7.5.8.7.5.8.
7.5.8. Total
TotalTotal
Total Operation
Operation Operation
Operation
Total weight data and weighing count of each material code or recipe code.
Concerning Parameters of the Function
Using F1 ~ F4 key for total
[0tHf- 2] to [0tHf- 5]
[Function] - [Function setting] - [General] - [Other]
Using the I/O terminals for total
[1n f-nn] nn: terminal number of the I/O.
[Function] - [Function setting] - [Control I/O] - [Input]
Using the parallel terminals for total
[05 f-nn] nn: terminal number of the option.
n: slot number installed the option.
[Function] - [Function setting] - [slot n] - [OP-05]
7.5.9.
7.5.9.7.5.9.
7.5.9. Undoing the Total Operation
Undoing the Total OperationUndoing the Total Operation
Undoing the Total Operation
Assign an operation input to undo the last result.
Refer to "10.4. Parameter List" of the function list regarding key function.
7.5.10.
7.5.10.7.5.10.
7.5.10. Clearing (Deleting) the Totaled Data
Clearing (Deleting) the Totaled DataClearing (Deleting) the Totaled Data
Clearing (Deleting) the Totaled Data
Total data can be deleted (cleared) using the preset operation input.
There are four types of clearing the data.
Assign an operation input to undo the last result on the function list.
Refer to "10.4. Parameter List" of the function list regarding key function.